15,662 research outputs found

    Users manual for the Automated Performance Test System (APTS)

    Get PDF
    The characteristics of and the user information for the Essex Automated Performance Test System (APTS) computer-based portable performance assessment battery are given. The battery was developed to provide a menu of performance test tapping the widest possible variety of human cognitive and motor functions, implemented on a portable computer system suitable for use in both laboratory and field settings for studying the effects of toxic agents and other stressors. The manual gives guidance in selecting, administering and scoring tests from the battery, and reviews the data and studies underlying the development of the battery. Its main emphasis is on the users of the battery - the scientists, researchers and technicians who wish to examine changes in human performance across time or as a function of changes in the conditions under which test data are obtained. First the how to information needed to make decisions about where and how to use the battery is given, followed by the research background supporting the battery development. Further, the development history of the battery focuses largely on the logical framework within which tests were evaluated

    The Thousand Aviator Study - Smoking history correlates of selected physiological, biochemical, and anthropometric measures

    Get PDF
    Smoking history correlates of selected physiological, biochemical, and anthropometric measure

    Trends in systolic blood pressure in the thousand aviator cohort over a 24-year period

    Get PDF
    Age, weight, and parental longevity effects on trends in systolic blood pressure in thousand aviator cohort over 24 year perio

    Thermal and Non-thermal Plasmas in the Galaxy Cluster 3C 129

    Get PDF
    We describe new Chandra spectroscopy data of the cluster which harbors the prototypical "head tail" radio galaxy 3C 129 and the weaker radio galaxy 3C 129.1. We combined the Chandra data with Very Large Array (VLA) radio data taken at 0.33, 5, and 8 GHz (archival data) and 1.4 GHz (new data). We also obtained new HI observations at the Dominion Radio Astrophysical Observatory (DRAO) to measure the neutral Hydrogen column density in the direction of the cluster with arcminute angular resolution. The Chandra observation reveals extended X-ray emission from the radio galaxy 3C 129.1 with a total luminosity of 1.5E+41 erg/s. The X-ray excess is resolved into an extended central source of ~2 arcsec (1 kpc) diameter and several point sources with an individual luminosity up to 2.1E+40 erg/s. In the case of the radio galaxy 3C 129, the Chandra observation shows, in addition to core and jet X-ray emission reported in an earlier paper, some evidence for extended, diffuse X-ray emission from a region east of the radio core. The 12 arcsec x 36 arcsec (6 kpc x 17 kpc) region lies "in front" of the radio core, in the same direction into which the radio galaxy is moving. We use the radio and X-ray data to study in detail the pressure balance between the non-thermal radio plasma and the thermal Intra Cluster Medium (ICM) along the tail of 3C 129 which extends over 15 arcmin (427 kpc). Depending on the assumed lower energy cutoff of the electron energy spectrum, the minimum pressure of the radio plasma lies a factor of between 10 and 40 below the ICM pressure for a large part of the tail. We discuss several possibilities to explain the apparent pressure mismatch.Comment: Accepted for publication in MNRAS. Refereed manuscript. 14 pages, 8 figures, additional panel of Fig. 3 shows asymmetric ICM distributio

    Stability, reliability and cross-mode correlations of tests in a recommended 8-minute performance assessment battery

    Get PDF
    A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests

    Isoprenoids enhance the stability of fatty acid membranes at the emergence of life potentially leading to an early lipid divide

    Get PDF
    Two key problems concern cell membranes during the emergence and early evolution of life: what was their initial composition, and why did the membranes of archaea and bacteria diverge? The composition of the first cell membranes could shed light on the most likely environment for the emergence of life. The opposing stereochemistry of modern lipid glycerol-phosphate headgroups in bacteria and archaea suggests that early membranes were composed of single chain amphiphiles, perhaps both fatty acids and isoprenoids. We investigated the effect of adding isoprenoids to fatty acid membranes using a combination of UV–visible spectroscopy, confocal microscopy and transmission electron microscopy. We tested the stability of these membranes across a pH range and under different concentrations of ionic species relevant to oceanic hydrothermal environments, including Na2+, Cl−, Mg2+, Ca2+, HCO−3, Fe3+, Fe2+ and S2−. We also tested the assembly of vesicles in the presence of Fe particles and FeS precipitates. We found that isoprenoids enhance the stability of membranes in the presence of salts but require 30-fold higher concentrations for membrane formation. Intriguingly, isoprenoids strongly inhibit the tendency of vesicles to aggregate together in the presence of either Fe particles or FeS precipitates. These striking physical differences in the stability and aggregation of protocells may have shaped the divergence of bacteria and archaea in early hydrothermal environments

    Algebras for parameterised monads

    Get PDF
    Parameterised monads have the same relationship to adjunctions with parameters as monads do to adjunctions. In this paper, we investigate algebras for parameterised monads. We identify the Eilenberg-Moore category of algebras for parameterised monads and prove a generalisation of Beck’s theorem characterising this category. We demonstrate an application of this theory to the semantics of type and effect systems

    CC255 Energy Uses in Nebraska Agriculture

    Get PDF
    Campaign Circular 255: This circular includes information about energy uses in Nebraska Agriculture including machine operations, irrigation, crop drying, and electrical energy use in general
    • …
    corecore